OnyxCeph 2024 (Build 3.2.223) Full

  • Full Version ✅
  • Multilanguage ✅
  • Supports Windows 7/8/8.1/10/11 ✅
  • 32/64 bits compatibility ✅
  • Single computer activation ✅
  • LIFETIME activation guaranteed ✅
  • Install guide is included ✅
Total Sold: 15
Tags: , , , , ,

$290.00

Description

OnyxCeph 2024 (Build 3.2.223) Crack

Changes in this build

  • Image acquisition 3D: Multiple wildcard expressions separated by ; can now be used
  • Vatech X-ray system: New software version of the interface to VCaptureSW.exe is supported
  • The Vatech interface has been revised and adapted to the new software version
  • All 3D modules: Improved visualization of transparent objects
  • Ceph 3D module: Prevented possible movement of reference points when clicked without dragging
  • 3D Export: Negative attachments will not longer be blocked out by interdental support material
  • Aligner: Negative attachments retain the original outer surface in direct exported Aligners
  • All 3D modules: Improved performance when setting or dragging points on 3D objects
  • For Export Directories, the save dialog is viewed with the correct directory
  • CT in 3D image acquisition: types CT_HEAD_SCAN and OVERLAY_3D are automatically assigned and checked
  • Aligner: Additional objects can be restricted in steps and can have a reference in the opposite jaw
  • Placeholder: With the new “AGE” macro, the patient’s age can be transferred
  • 3D Export: Additional 3D objects can be moved for a better fitting them to the model
  • Server: transport encryption with different AES methods can be configured
  • 3D Export: Better vertical blockout material available as new additional object
  • Aligner-Splint Export: Vertical blockout available as new option
  • Modules V.T.O.3D, Aligner, Approval: Optional IPR display allows changing values directly in the 3D view
  • 3D Export: Improved automatich repair of extremely deformed softtissue
  • V.T.O.3D, Aligner: Improved computation speed and handling of extreme cases in soft-tissue simulation
  • Textured .PLY files from the SHINING IOS scanner can be read
  • Edit3D: Optimization of computation, robustness and visualization
  • OrthoApps,BiteSplint: Improved speed of undo/redo functionality for complex constructions
  • Text options of the comment field in the Patient tab can be saved as default and restored
  • 3D Export: Optimized labeling presets for segmented models and single jaws
  • Image Acquisition 2D: images in JPEG2000 format can be imported
  • Improved error messages for failed HTTP downloads
  • WireBonding: Harmonized shortcuts for bracket alignment, Undo keeps brackets tagged now
  • FA_Bonding: Ruler for bracket placement is now only shown on selected brackets
  • Retainer: Distance to model can be changed separately.
  • Import Multipage-DICOM: The alignment of the planes is recognized correctly.
  • The <VAL|%?|???> macro now works again for patient, image or session notes
  • New placeholders for the patient’s treating doctor %{treat:short}, %{treat:firstname} and %{treat:lastname}
  • Ceph 3D module: After undo with Ctrl+Z, 2D/3D errors no longer occur
  • CLI: The common transfer of image data via -PicPath#= and -PicImportPath= is now possible
  • OnyxVDDSPicI can also be used to import textured .PLY or .OBJ files
  • Data import from MotionView (patient, 2D and 3D data) is now available
  • V.T.O.3D, Aligner: Crown navigator restores previous view settings
  • In the context menu item “Delete all points” you will find a submenu “Only active points” or “All”
  • Interface for data import from RELU® Creator added
  • Combined 3D image acquisition now also works with multi-page DICOMs and the use of an ROI
  • The texture is loaded for 3D OBJ files with double spaces in the file name
  • OrthoApps,BiteSplint: Additional button allows easy sorting of construction parts
  • Bracket library: Last full-text search and sorting is restored; All column filters can be deleted simultaneously
  • BiteSplint: Improved automatic detection of interior side for complex splint parts
  • Finding Compare: Chosen compare colors are used also for tracing of single images
  • Aquire 3D: Acquisition of MultiPage DICOMs via Drag&Drop is possible
  • Local OnyxCeph instance is terminated before registration
  • Full screen view: Monitor change via keyboard shortcut [Ctrl]+[M] or [Shift]+[Ctrl]+[M]
  • Server: Installation path of the service is always enclosed in quotation marks for security reasons.
  • Server: improved performance during server startup
  • Edit3D: New tool for selection of processable surface regions
  • BiteSplint: Improved splint border geometry
  • When a patient is first admitted, a check is made to see whether it already exists
  • OnyxQuery: After new parameter -DeleteOnReady a temporary file can be passed
  • Full text search for template dialogs added
  • TADmatch: Added option for contact surface (collar) in the mounting model for improved vertical position
  • Multi-page printout under High-DPI retains the defined font size of the print template for all pages.
  • The original order of the landmarks can be re-established in the system options
  • HTTP Interface accepts image data; Transfer of packed image files via tag CLI:PicImportZIP supported
  • The new HTTP interface option “[ ] Export data” can be used to prevent patients from being queried via HTTP
  • All 3D modules: Double-clicking the object list selects objects with similar names
  • SFTP upload now works in cases where some directories in the upload path don’t have read permissions
  • Patch export for media trees corrected.
  • Edit3D: Replaced local repair tool with option to repair complete object
  • Digitize 3D: Landmarks can be moved using the cursor keys in the 3D view
  • Print Editor: Finding relation handled more consistent, esp. under multiselection
  • Print Editor: Manipulation and updates of 3d views in print elements more consistent now

OnyxCeph³™ is a Client-/Server Windows software with a powerful SQL database that is approved as a medical product for the processing of 2D and 3D data, mainly in

  • Archiving,
  • Image Based Diagnostics,
  • Treatment Planning and
  • Patient Education

in general dentistry, orthodontics and maxillofacial surgery.

The software development concept guarantees best practices, professional competence and flexibility but also the involvement of latest database and programming techniques and integration of new hardware technology.

Especially the underlying so-called Integrative Cephalometric Concept 2D|3D ensures that depending on requirements and technical equipping tried and tested methods in diagnostics and treatment planning can be used together with state-of-the-art technologies mutually and consistently.

Functionality

  • Patient Management

Manage all patient data and documents which are relevant for diagnosis and treatment planning purposes. Synchronize patient records with your practice management software and the data of all used image sources. Classify treatment types, sessions and findings for statistical evaluation and long-term treatment analysis.

  • Image Data 2D|3D

Here you can acquire, load, manage, process and analyze all 2D and 3D data patient-relatedly. Several modules are available, such as cephalometric analysis and measurements, image combine, mirror symmetry analysis, CO | CR comparison, Ricketts V.T.O., treatment simulation, superimposition, adjust image, edit image, clone finding, export, send, image compare, forms, 100%  printing etc.

Select one or multiple of about 100 pre-installed cephalometric analyses or create and order your customized home analysis.

  • Presentation

Create presentation layouts according to your own suggestions and present your image and finding data PowerPoint-like. For patient education purposes, you can organize case examples (images, movies, animations) in specific tree-structured albums.

  • Letters

Create and design your own print forms for letters to patients, referring doctors, or specialists or other layouts which automatically can integrate patient data, treatment information, images, diagnostic results and treatment plans. Manage these letters within the database, as external PDF, or, print out on paper.

  • Forms

Use the forms functionality to manage, display and fill out externally created DHTM forms on the screen,

e.g. for anamnesis, clinical findings, functional diagnistics or other issues.

  • Online

Use the intergrated web browser to access required information online without switching applications.

Stability

SQL database NEXUS which is used together with OnyxCeph™ for many years already ensures a high degree of stability and reliability of the client/server application in a network environment as well as a fast and stable database access via TCP/IP independent on the total number of managed patient and image data records. With a fix IP address and suited access permissions on the server, this also will allow you to access your data online when working outside the practice.

Easy Of Use

In the style of modern Windows™- applications, the graphical user interface (GUI) arranges functions belonging together with all related inputs and controls on separate tab sheets.

System calls and settings can be changed by the menu of the OnyxCeph³™ start button. Also the selection of practice and patient can be done in the main form window of the OnyxCeph³™ host application. For qualified users with good Windows™ knowledge this allows to use the basic functionality of the program without intensive introduction.

Configurability

Individualize your application by customized settings for the clients and/or the system as a whole. This is possible e.g. for server and client language, image sources, image types and image type settings, sessions, analyses, graphic options, print form templates, presentations, media libraries and DHTML-forms.

Integration

OnyxCeph³™ provides individual and default interfaces to practice management software and databases but also to firmware and software for imaging systems and 3rd party applications. Set up relevant interfaces on each client for data import, data exchange, and links for frequently used 3rd party programs.

0